1989
Varen er på lager.
Varen er bestilt fra leverandør og leveringsdato er bekreftet.
Varen er bestilt fra leverandør, men leveringsdato er ikke bekreftet.
Varen må bestilles fra leverandør.
Varen befinner seg på fjernlager.
Varen er bestilt fra leverandør, men leveringsdato er ikke bekreftet.
Varene bestilles fra vår leverandørs lager.
Ubekreftet - Ta kontakt med kundesenter for nærmere informasjon.

 Handlevogn

Handlevognen er tom.

 

Ex Cable Glands CR-1BR/20/M20 Brass

IP66&IP68@25m EExde IIC

Varenr:
CR1BR20M20
CR1BR20M20 Peppers  Ex Cable Glands CR-1BR/20/M20 Brass IP66&IP68@25m EExde IIC
CR1BR20M20 Peppers  Ex Cable Glands CR-1BR/20/M20 Brass IP66&IP68@25m EExde IIC
.

Cable Gland Type CR (featuring "CROCLOCK®")
 
"CR"type glands, certified Flameproof Ex d, Increased Safety Ex e & Restricted Breathing Ex nR are suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, liB and lie. They provide a controlled Ex d & IP displacement seal on the cable inner sheath minimising damage to cables that exhibit "cold flow" characteristics, an environmental seal on the outer sheath and "CROCLOCK"", a unique non reversible multi clamping system for wire (W), braid (X) and tape (Z) armoured cables.
The gland maintains IP66 & IP68 to 2S metres and is deluge proof without the use of an additional seal or deluge boot. It is supplied with an IP O-ring seal as standard on metric entry threads. Options are available for use with lead sheath, LSOH cables and extreme temperature applications.
 
Compliance Standard: EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 61241-0, EN 61241-1, IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1 & IEC 60529
 
Certification:
ATEX: II2 GD Exd IIC/ Ex eII/Ex tD A21 II3 GD Ex nR II
IECEx: Ex d IIC / Ex eII / Ex tD A21
GOST-R: ExdIICU / ExeIIU
CSA: Ex d IICI Ex ell Class I Zone 1; Class I Division 2, Groups A, B, C & D; Class II Division 2, Groups E, F & G; Class Ill, Enclosure Types 3, 4 & 4X
NEPSI: Ex d IICI Exe II
INMETRO: BR - Ex d IIC / Ex eII / Ex nR II / Ex tD A21
ABS: 1-1-417.7,4.8-3/1.7,4-8-3/13 and 4-8-4/27.5; MODU Rules 4-3-3/9
LLOYD'S: Enclosure Systems (Part 1B)
RMRS: Part XI of Rules for sea-going ships (ed.2008)
 
Certificate No.:
ATEX: BAS 01ATEX2271 X & SIRA 09ATEX1221 X
IECEx: SIR 07.0099X
GOST-R: POCC GB.r606.B00853
CSA: CSA 1356011
NEPSI: GYJ06189X
INMETRO: NCC 5877/09 X
ABS: 09-LD463991-PDA
LLOYD'S: 10/00056
RMRS: 09.00784.011
 
IP Rating: IP66 & IP68 (25 metres - 30 minutes), NEMA 4X & DTS01 1991
 
Operating Temperature:
Neoprene Seals -20°C to +85°C
Silicone Seals -60°C to + 180°C
 
Materials: Brass or Stainless Steel
Plating: Nickel - Zinc


Copyright © 2024 Marin Supply. All rights reserved.
Forretningssystem og nettbutikkløsning levert av Multicase™ Norge AS